Your Local Instrumentation Expert
We can design and manufacture products tailored to the user’s specific needs and requirements to address a wide range of flow measurement needs.
Multi-Pipeline Wastewater & Raw Water Flow Measurement Solution
Published:
2026-05-11
Summary
Project Background
In municipal wastewater systems and industrial plants, multiple outdoor pipelines are often used for raw water intake, sewage conveyance, sludge return and effluent discharge. Reliable flow measurement is critical for process control, water balance analysis, compliance reporting and operational cost management. However, scattered outdoor pipelines, humid environments, corrosive fluids and suspended solids easily cause instrument failure, blockage and measurement drift.
On-Site Challenges
1.Complex outdoor installation environment Pipelines are exposed to rain, dust, humidity and temperature changes. Ordinary instruments are prone to water ingress, corrosion and accelerated aging.
2.Abrasive and impurity-laden fluids Raw water, sewage and industrial wastewater contain sediment, suspended solids and fibrous impurities, which can wear, block or drift traditional mechanical meters.
3.Scattered multi-pipeline layout Multiple parallel pipelines require separate measurement points. Manual reading and on-site maintenance are inefficient and lack real-time data visibility.
4.Stable measurement under variable flow Flow rates may fluctuate significantly between day and night. The solution must maintain reliable accuracy at both high and low flow conditions.
Our Solution
We deployed an integrated multi-point flow measurement system using flange-mounted electromagnetic flow meters on each key outdoor pipeline. The meters are equipped with IP67 transmitters, corrosion-resistant liners and stainless steel electrodes, and are connected to the central control system through digital communication.
Specific Products Used
● Product Name: Flange-Type Electromagnetic Flow Meter
● Application Type: Outdoor wastewater, raw water and industrial effluent measurement
● Connection: Standard flange connection, suitable for existing field pipelines
● Lining: PTFE or polyurethane lining, resistant to corrosion and abrasion
● Electrode: 316L stainless steel electrode
● Protection: IP67 transmitter housing
● Communication: 4-20mA analog output and RS485 Modbus
● Optional Function: Pulse output, data logging, remote monitoring
Solution Advantages
1.High protection for outdoor use IP67 sealed transmitters resist rain, dust, humidity and temperature fluctuations, reducing failure rates in harsh field conditions.
2.Clog-free and wear-resistant structure The full-bore design has no moving parts, avoids additional pressure loss, and effectively solves blockage and wear problems caused by sediment and impurities.
3.Accurate measurement over a wide flow range The electromagnetic principle ensures stable measurement even under variable flow conditions, supporting both high-flow water transfer and low-flow operation.
4.Easy installation and low maintenance Standard flange mounting adapts quickly to existing pipelines. There is no mechanical wear, so regular disassembly, cleaning and calibration are greatly reduced.
5.Centralized monitoring RS485 Modbus communication enables unified data upload to the plant SCADA system, realizing real-time monitoring, historical data recording and operation scheduling.
Applicable Scenarios
● Municipal wastewater plant inlet and outlet pipelines
● Industrial wastewater discharge pipelines
● Raw water intake and water transfer pipelines
● Sludge return and reclaimed water pipelines
● Outdoor multi-pipeline flow monitoring systems
Recommended Product

Electromagnetic flowmeter
More Solution