Product
Insertion type Electromagnetic Flowmeter
The Insertion Type Electromagnetic Flowmeter provides accurate and reliable measurement of conductive liquids, especially in large-diameter pipelines. Its insertion design enables easy installation and maintenance while providing a cost-effective flow measurement solution.
Keywords:
Category:
Product
Flow meter
Electromagnetic Flow Meters
- Description
-
Core Overview
The Insertion Type Electromagnetic Flowmeter provides reliable and accurate flow measurement for conductive liquids, especially in large-diameter pipelines. With a compact insertion design, it offers easy installation, convenient maintenance and a cost-effective alternative to full-bore electromagnetic flowmeters.
Suitable for water, wastewater, cooling water, process liquids and other conductive media, it is widely applied in water treatment, industrial process control, chemical, HVAC and other applications.
Specification
Name
Insertion type Electromagnetic Flowmeter
Nominal Pressure
1.6MPa
Flow Velocity Range
0.3–12 m/s (extended range: 0.1–15 m/s)
Electrical Conductivity
≥ 5 μS/cm
Electrode Material
Mo-bearing stainless steel 0Cr18Ni12Mo2Ti, Hastelloy C-276, Titanium Ti, etc.
Measuring Tube (Sensor Head) Material
ABS
Housing Material
304 stainless steel
Sensor Output Signal
0.209 mV·p⁻¹/m/s
Signal Cable Length
10 m standard (remote type); maximum distance between sensor and transmitter: 50 m (contact factory for special requirements)
Enclosure Protection Class
IP68, in accordance with GB-08-64 standard
Transmitter Power Supply
220VAC, 24VDC, lithium battery supply optional
Signal Output
Standard: pulse, frequency, 4-20mA current, Modbus communication
Optional: HART protocol, GPRS, PROFIBUS, etc.
Overall Power Consumption
7W (external power supply)
Operating Environment
Ambient temperature: -25 ~ +60℃; Humidity: 5% ~ 90%
Explosion Proof Grade
Non-explosion-proof; Explosion-proof type: Exd ib mb IIC T6 Gb
Working Principle

The insertion electromagnetic flow sensor is a velocity-type liquid flow measuring instrument based on Faraday’s Law of Electromagnetic Induction.
A miniature electromagnetic flow sensor is inserted into the pipeline via a long rod at a specified depth. When conductive liquid flows through the working magnetic field generated by the excitation coil, it cuts the magnetic field lines and induces an electromotive force across a pair of electrodes. The induced voltage is proportional to the magnetic flux density (B), electrode spacing (L) and local flow velocity (V):
E = B × L × V
Two standard insertion configurations are defined:
- For pipes ≤ DN400: The sensor is placed at the pipe centerline to measure the maximum point velocity. The average pipe flow velocity is obtained by multiplying the measured maximum velocity by a correction coefficient K, calculated from the Reynolds number and pipe wall roughness.
- For pipes > DN400: The sensor is inserted to a depth of 0.121D (D = inner pipe diameter) from the inner wall. At this position, the measured local velocity equals the average flow velocity of the full pipe (K = 1).
The total volumetric flow rate is calculated as:
Q = V × A where A is the cross-sectional area of the pipe.
Since B and L are factory-calibrated constants and pipe cross-section A is a known fixed value, the induced electromotive force E directly corresponds to the actual pipeline flow rate.

Key Features
● Cost-Effective for Large-Diameter Pipes Significantly lower cost than full-bore flanged flowmeters for large pipelines. The larger the pipe diameter, the higher the cost advantage, making it the most economical solution for DN150 and above pipe flow measurement.
● Hot-Tap Installation Without Process Shutdown Supports online hot-tap mounting via ball valve assembly. Installation and maintenance can be completed without pipe cutting or production interruption, ideal for continuous-operation industrial systems.
● Compact & Lightweight Design Small overall size and light weight allow single-person installation, greatly reducing transportation, hoisting and on-site construction costs compared with full-bore models.
● Stable & Reliable Measurement Operates on Faraday’s Law of Electromagnetic Induction. Readings are unaffected by fluid density, viscosity, temperature and pressure, delivering consistent performance for raw water, wastewater, sludge and circulating water.
● Ultra-Wide Pipe Size Coverage Adaptable to pipe diameters from DN150 up to DN3000 and larger custom sizes, covering municipal trunk lines, large water conveyance projects and industrial main pipelines.
● Minimal Pressure Loss The small sensing probe causes negligible flow resistance and pressure drop in the pipeline, which saves energy consumption of the pumping system and does not affect normal pipeline delivery.
● Flexible System Integration Standard outputs include 4-20mA analog, pulse frequency and Modbus RTU. Optional HART, GPRS and PROFIBUS enable seamless connection to SCADA systems for remote flow monitoring.
Applications
● Municipal water supply trunk lines, urban drainage mains and long-distance water conveyance pipelines
● Inlet and outlet mains of wastewater treatment plants, and large-diameter sludge pipelines
● Circulating water, cooling water and make-up water pipelines in power generation plants
● Water conservancy irrigation projects, inter-basin water transfer and agricultural water supply systems
● Industrial circulating water systems in petrochemical, metallurgical, papermaking and textile industries
● Large-diameter process pipelines in industrial manufacturing and raw material delivery systems

Previous
Next
Need more information?
Contact us to learn more about our flow meters, solutions, and services
More Products
The company's product range includes flow meters, level gauges, and temperature, pressure, and display instruments.