Product
Corrosion-resistant electromagnetic flowmeters
The Corrosion-resistant electromagnetic flowmeters is designed for precise measurement of conductive liquids in a wide range of industrial applications. With a durable PE lining.
Category:
Product
Flow meter
Electromagnetic Flow Meters
- Description
-
Core Overview
The Corrosion-resistant electromagnetic flowmeters is designed for precise measurement of conductive liquids in a wide range of industrial applications. With a durable PE lining, high measurement accuracy, no moving parts, and low maintenance requirements, it provides a dependable and cost-effective solution for water treatment, wastewater, irrigation, and general industrial flow measurement.
It is especially suitable for applications involving clean water, sewage, slurry, and other conductive liquids containing suspended solids or particles.
Working Principle
The electromagnetic flow meter operates according to Faraday’s Law of Electromagnetic Induction. When a conductive liquid flows through the magnetic field inside the meter, a voltage signal is generated in proportion to the flow velocity. The transmitter converts this signal into flow data, allowing accurate measurement of volume flow.
Because the measurement is not affected by pressure, temperature, density, or viscosity in most applications, electromagnetic flow meters are widely recognized as a reliable solution for conductive liquid measurement.
Typical Applications
● Water Treatment and Water Supply Systems: Used for flow monitoring and control of raw water, tap water, reclaimed water, and wastewater.
● Chemical and Pharmaceutical Industries: Suitable for metering corrosive liquids such as acid, alkali, and salt solutions, as well as pharmaceutical intermediates.
● Food and Beverage Production: Used for flow measurement of sanitary-grade liquids such as fruit juices, dairy products, beverages, and condiments; can be configured with food-grade linings and electrodes.
● Metallurgy and Mining: Used for measuring liquids containing solid particles, such as slurry, mud, and cooling water; wear-resistant electrodes help extend service life.
● Power and Energy: Used for flow monitoring in power plant desulfurization systems, circulating cooling water, and wastewater treatment.
Product Features
1. High Measurement Accuracy
Using advanced electromagnetic flow measurement technology, the meter delivers accurate, stable, and repeatable results. It is ideal for process control, flow monitoring, and liquid metering applications.
2. PE Lining with Good Corrosion Resistance
The PE lining offers reliable resistance to many common corrosive media, including acids, alkalis, and salt solutions. This makes the flow meter suitable for a variety of industrial and water treatment environments.
3. No Moving Parts
The meter has no internal moving components, which helps reduce mechanical wear and minimizes the risk of failure. This design ensures long-term stability and lower maintenance costs.
4. Full-Bore Structure, No Pressure Loss
With no obstruction inside the measuring tube, the flow meter does not create additional pressure drop. This helps improve system efficiency and maintain smooth liquid flow.
5. Suitable for Liquids with Solids or Particles
The unobstructed measuring tube allows the meter to perform well in applications involving wastewater, sludge, slurry, and other liquids containing suspended solids, sand, or particles.
6. Good Electrical Insulation Performance
The PE material provides excellent insulation, which supports stable signal transmission and helps ensure reliable measurement performance.
7. Cost-Effective Solution
Compared with some higher-grade lining materials, PE offers a practical balance between performance and cost, making it an economical choice for many standard applications.
Specification
Name
Corrosion-resistant electromagnetic flowmeters
Product Type
Electromagnetic Flow Meter
Nominal Diameter
DN10 – DN3200
Accuracy
±1%
Applicable Medium
Conductive liquids
Minimum Conductivity
≥5 μS/cm
Lining Material
PTFE, PFA, PE
Electrode Material
316L Stainless Steel, Hastelloy B, Hastelloy C, Titanium, Molybdenum, Platinum-Iridium, Tungsten Carbide, Scraper Electrode
Connection Type
Flange connection
Output Signal
4-20mA, Pulse, RS485; HART (optional), 4-20mA with HART (optional)
Power Supply
24VDC / 220VAC
Power Consumption
< 20W
Protection Class
IP65 / IP67 / IP68 (optional)
Medium Temperature
Subject to lining material specifications
Ambient Condition
Temperature: -25℃ ~ +60℃ (standard industrial environment)
Humidity: 5% ~ 90%
Standard Functions
High/low alarm, excitation alarm, empty pipe alarm, self-diagnosis
Display Units
L/s, L/m, L/h, m³/s, m³/m, m³/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Operation Languages
English, Chinese, Italian, Portuguese, French, Spanish, Korean
Optional Configurations
To meet different application requirements, the PE Electromagnetic Flow Meter can be supplied with optional features such as:
● 0.5 Class Accuracy(±0.5%)
● Integrated type or remote type
● Different electrode materials for various media
● Multiple communication protocols
● Battery-powered version
● Explosion-proof design
● IP68 protection for submerged applications
Magnetic Flow Meter Electrode Material Selection
Electrode Material
Applications & Properties
SUS316L
Applicable to industrial/municipal water, wastewater and low corrosive mediums.
Widely used in petroleum, chemical industries.Hastelloy B
Strong resistance to hydrochloric acids below the boiling point.
Resist against oxidable acids, alkali and non-oxidable salts. For instance, vitriol, phosphate, hydrofluoric acids, and organic acids.Hastelloy C
Exceptional resistance to strong solutions of oxidizing salts and acids. For example, Fe+++, Cu++, Nitric acids, mixed acids
Titanium
Titanium can withstand corrosive mediums such as seawater, chloride salt solutions, hypochlorite salts, oxidable acids(including fuming nitric acids), organic acids, and alkali.
Not resistant to high purity reducing acids such as sulphuric acids, hydrochloric acids.Tantalum
Highly resistant to corrosive mediums.
Applicable to all chemical mediums except Hydrofluoric Acids, Oleum and Alkali.Platinum-iridium
Applicable to all chemical mediums except for Ammonium salts and Fortis
Magnetic Flow Meter Flow Range
size Flow Range
(mm) Qmin(m³/h) Qmax(m³/h) 10 0.085 3.4 15 0.19 7.63 20 0.34 13.56 25 0.53 21 32 0.87 34 40 1.36 54 50 2.12 85 65 3.6 150 80 5.43 200 100 8.48 300 125 13.25 500 150 19.1 750 200 33.9 1350 250 52.9 2100 300 76.3 3050 350 103 4100 400 135 5400 450 170 6800 500 220 8400 600 305 12000 700 420 16600 800 550 21700 900 690 27400 1000 850 33900 1200 1220 48800 1400 1670 66400 1600 2170 86000 1800 2700 109800 2000 3400 135600 2200 4103 164134 2400 4883 195333 2600 5731 229245 ... Contact us to get more Magnetic Flow Meter Selection Guide
type Electromagnetic Flowmeter Nominal Diameter 006 DN6 065 DN65 401 DN400 142 DN1400 008 DN8 080 DN80 451 DN450 162 DN1600 010 DN10 101 DN100 501 DN500 182 DN1800 015 DN15 125 DN125 601 DN600 202 DN2000 020 DN20 151 DN150 701 DN700 222 DN2200 025 DN25 201 DN200 801 DN800 242 DN2400 032 DN32 251 DN250 901 DN900 262 DN2600 040 DN40 301 DN300 102 DN1000 280 DN2800 050 DN50 351 DN351 122 DN1200 302 DN3000 Structural Type F Remote Type Y Integrated Type Connection Method A Flange connection
B Threaded connection
K Tri-clamp connection
D Flange clamp type
F Union connection
Nominal Pressure (MPa) 16 1.6Mpa 25 2.5Mpa
40 4.0Mpa
others Customizable
Electrode Material 1 SUS316L 2 Tantalum
3 Titanium
4 Hastelloy В 5 Hastelloy С
6 Platinum-iridium alloy
7 Stainless steel coated with tungsten carbide
8 Scraper electrode
Sensor Material B Carbon steel
A SS304 A1 SS316 Object Protection M IP65/67 H IP68 Power Supply 1 220V
2 24V
3 220V+24V
4 12V low power consumption
5 3.6V lithium battery
Signal Output
/ CommunicationA 4-20mA H HART R RS485 G GRPS others Agreements
Installation
Electromagnetic Flow Meter Installation Requirement
In order to obtain stable and accurate flow measurement, it is very important that the flow meter is installed correctly in the piping system. Do not install the meter near equipment that produces electrical interference, such as electric motors, transformers, variable frequency drives, power cables, etc. Avoid locations with pipe vibrations, for example near pumps. Do not install the meter close to pipeline valves, fittings, or other obstacles that can cause flow disturbances. Install the meter in a location where there is sufficient access for installation and maintenance.
lnstall at the lowest point and vertical upward direction. Don't install at the highest point or vertical downward diection

When drop is more than 5m, install exhaust valve at the downstream

lnstall at the lowest point when used in open drain pipe

Need 10D of upstream and 5D of downstream

Dont' install it at the entrance of pump, install it at the exit of pump

Previous
Need more information?
Contact us to learn more about our flow meters, solutions, and services
More Products
The company's product range includes flow meters, level gauges, and temperature, pressure, and display instruments.